勤益科大機構典藏:Item 987654321/6741
English  |  正體中文  |  简体中文  |  Items with full text/Total items : 2928/5721 (51%)
Visitors : 375584      Online Users : 302
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
Scope Tips:
  • please add "double quotation mark" for query phrases to get precise results
  • please goto advance search for comprehansive author search
  • Adv. Search
    HomeLoginUploadHelpAboutAdminister Goto mobile version


    Please use this identifier to cite or link to this item: http://ir.lib.ncut.edu.tw/handle/987654321/6741


    Title: Experimental Investigation of a Machine Tool Cooler Using Hot-gas By-pass Valves for Temperature Control
    Authors: 王輔仁
    Contributors: 冷凍空調與能源系
    Date: 2011-02
    Issue Date: 2017-11-29 09:52:43 (UTC+8)
    Abstract: Machine tool with more accurate, stable and higher precision for the machining components cannot be developed without the precise control of the temperature rise by appropriate cooling. The machine tool coolers are the best managers of oil (or water) temperature in avoiding the deviation of spindle centerline for machine tools. However, the machine tool coolers are facing the control hunting of cooling temperature and the dramatic variation of heat load during high speed machining. In this study, the experimental investigation using hot-gas by-pass scheme were conducted to evaluate the temperature control accuracy of process cooling water. Effects of delay time control use pulse width modulation (PWM) techniques for by-pass valve under variation of process cooling load and different throttling devices been have investigated. The accuracy of temperature control as well as the frequency of ON-OFF times under different loading and different delay time has been compared comprehensively. The experimental results revealed that control accuracy within 0.2 °C (0.36 °F) of cooling water temperature can be achieved with 5 seconds delay time controlled by adjusting hot-gas by-pass valve. The proposed hot-gas by-pass cooling system with PWM controlled time delay scheme is not only more cost-effective than inverter-driven system, but also can provide higher durability for by-pass solenoid valve and perform precise temperature control specific for high-accuracy process cooling application. © 2011 ASHRAE. (15 refs)
    Relation: ASHRAE Transactions
    Appears in Collections:[Department of Refrigeration & Air Conditioning] 【冷凍空調與能源系】期刊論文

    Files in This Item:

    There are no files associated with this item.



    All items in NCUTIR are protected by copyright, with all rights reserved.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - Feedback