English
| 正體中文 |
简体中文
|
全文筆數/總筆數 : 2928/5721 (51%)
造訪人次 : 373579 線上人數 : 166
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by
NTU Library IR team.
搜尋範圍
全部NCUTIR
工程學院
冷凍空調與能源系(所)
--【冷凍空調與能源系】期刊論文
查詢小技巧:
您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
進階搜尋
主頁
‧
登入
‧
上傳
‧
說明
‧
關於NCUTIR
‧
管理
勤益科大機構典藏
>
工程學院
>
冷凍空調與能源系(所)
>
【冷凍空調與能源系】期刊論文
>
Item 987654321/6747
資料載入中.....
書目資料匯出
Endnote RIS 格式資料匯出
Bibtex 格式資料匯出
引文資訊
資料載入中.....
資料載入中.....
請使用永久網址來引用或連結此文件:
http://ir.lib.ncut.edu.tw/handle/987654321/6747
題名:
Performance Evaluation of Indoor Environment Parameters for an Unoccupied Operating Room
作者:
王輔仁
貢獻者:
冷凍空調與能源系
日期:
2011-01
上傳時間:
2017-11-29 10:03:15 (UTC+8)
摘要:
The HVAC systems for operating rooms are energy-intensive and sophisticated in that they operate 24 hours per day year-round and use large amount of fresh air to deal with infectious problems and to dilute microorganisms. However, little quantitative information has been investigated about trade-off between energy-efficient HVAC system and indoor environment quality especially when the operating room is not occupied. The objective of this study is to present the field measurement approach on performance evaluation of the HVAC system for an unoccupied operating room. Variable air volume terminal boxes were conducted to verify the compromise of energy-saving potential and indoor environment parameters including particle counts, microbial counts, pressurization, temperature and humidity. Field measurements of a full-scale operating room have been carried out at a district hospital in Taiwan. Numerical simulation has been applied to evaluate the air flow distribution and concentration contours while conducting the velocity reduction approach in the unoccupied operating room. The results reveal that it is feasible to achieve satisfactory indoor environment by reducing the supply air volume (or velocity) in the unoccupied operating room. Optimal face velocity of HEPA filter and percentage of damper opening for the variable air volume terminal boxes could be obtained through compromising of indoor environment quality control and energy consumption as well. It will stimulate a more robust investigation of infection-controlled, energy-efficient and environment-comfortable HVAC system specific for unoccupied operating rooms. © 2011 ASHRAE. (15 refs)
關聯:
ASHRAE Transactions
顯示於類別:
[冷凍空調與能源系(所)] 【冷凍空調與能源系】期刊論文
文件中的檔案:
沒有與此文件相關的檔案.
檢視Licence
在NCUTIR中所有的資料項目都受到原著作權保護.
DSpace Software
Copyright © 2002-2004
MIT
&
Hewlett-Packard
/
Enhanced by
NTU Library IR team
Copyright ©
-
回饋