勤益科大機構典藏:Item 987654321/6821
English  |  正體中文  |  简体中文  |  全文筆數/總筆數 : 2928/5721 (51%)
造訪人次 : 388078      線上人數 : 408
RC Version 6.0 © Powered By DSPACE, MIT. Enhanced by NTU Library IR team.
搜尋範圍 查詢小技巧:
  • 您可在西文檢索詞彙前後加上"雙引號",以獲取較精準的檢索結果
  • 若欲以作者姓名搜尋,建議至進階搜尋限定作者欄位,可獲得較完整資料
  • 進階搜尋


    請使用永久網址來引用或連結此文件: http://ir.lib.ncut.edu.tw/handle/987654321/6821


    題名: Removal of indoor airborne bacteria by the nano-Ag/TiO2 as photocatalyst: a feasibility study in museum and nursing institutions
    作者: 宋文沛
    貢獻者: 景觀系
    日期: 2011-03
    上傳時間: 2017-12-17 10:16:08 (UTC+8)
    摘要: Deterioration of indoor air quality attributable to airborne bacterial consortia is a widespread environmental problem. The main objective of this study is to evaluate the feasibility of applying the syngetic effect of nano-Ag/TiO2Ag/TiO2 as a photocatalyst and UV light to enhance the disinfecting capability of full-scale bacterial restraining equipment on-site in the National Museum of Natural Science and a medical-nursing institute. The influence of initial counts of total airborne bacteria and volume of space on the efficiency of bacterial restraining have been studied. In the case of museum application, a higher initial total bacterial count leads to better bacterial restraining rates; Site A (initial total bacterial counts = 506  CFU/m3506  CFU/m3) has the best bacterial restraining rate (92%) as compared with Site B (69%, initial total bacterial counts = 158  CFU/m3158  CFU/m3) and Site C (80%, initial total bacterial counts = 338  CFU/m3338  CFU/m3) after 24 h of operation. Higher initial counts of total airborne bacteria lead to an increasing bacterial restraining rate. Approximately 92% (Site A) and 74% of restrained bacterial rate were observed in a museum and nursing institutions, respectively, under the similar initial total airborne bacterial counts (506, 598  CFU/m3598  CFU/m3). The results illustrate that changes in the volume of space do not have significant inhibitory effects on the efficiency. The proposed equipment can disinfect air to restrain bacteria effectively, as demonstrated on-site in museums and nursing institutions; the results will be valuable references for designing a full-scale commercialized device for large-scale applications in the future.
    關聯: Journal of Environmental Engineering, ASCE
    顯示於類別:[景觀系(所)] 【景觀系】期刊論文

    文件中的檔案:

    沒有與此文件相關的檔案.



    在NCUTIR中所有的資料項目都受到原著作權保護.


    DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU Library IR team Copyright ©   - 回饋